Proportional pressure
The pump maintains the pressure with relation to the
Max
Min
H
Q
Hset*HQ%
Hset
current ow. The pressure is equal to the set
pressure (Hset on the drawing) at maximum
power; at 0 ow it is equal to HQ%(default 50%,
HQ% can be set on the pump webpage) of the
set pressure. In between, the pressure changes
linearly, relative to the ow.
In regulated mode we can only set the pump pressure (Hset on the drawing).
We can only scroll through the other parameters.
Constant pressure
The pump maintains the currently set pressure (Hset on
Max.
Min.
Hset
H
Q
the drawing), from 0 ow to maximum power, where the
pressure begins to drop.
At constant pressure, we can only set the pressure
(Hset on the drawing) which the pump will maintain.
We can only scroll through the other parameters.
Constant speed
The pump operates with the currently set speed (RPMset
Max.
H
Q
Min.
RPMset
on the drawing).
In the unregulated mode, we can only set the speed
at which the pump will operate. We can only scroll
through the other parameters.
Combined mode
Multiple limits can be set only over the web interface. None of the other
modes are on.
5.2.1 Twinpumpoperation
During normal operation, only one pump is active, while the other is in
standby. Pumps change duty once per day. Every pump operates according
to its own settings, so parameter changes should be made on both pumps. If
any pump detects an error or loss of communication, the standby pump will
start in less than 15 seconds.